{lead}
{name}
  • {name}
  • 日本語
  • English (Global)
  • English (Asia Pacific)
  • 简体中文
  • 繁體中文
  • 한국어
Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Digital Fiber Sensor FX-100

  • Basic Information

  • Order guide

  • Option

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Sensing characteristics

  • List of fibers

  • Cautions For Use

Basic Information

Taking fiber sensors to the next level

      Order guide

      Amplifiers

      TypeAppearanceModel No.Emitting elementOutput
      Standard
      type
       

      FX-101 (Note 2)Red LEDNPN open-collector
      transistor
      FX-101P (Note 2)PNP open-collector
      transistor
      M8 plug-in
      connector type
      FX-101-Z (Note 3)NPN open-collector
      transistor
      FX-101P-Z (Note 3)PNP open-collector
      transistor
      Cable set
      (Note 1)
      FX-101-CC2NPN open-collector
      transistor
      FX-101P-CC2PNP open-collector
      transistor
      Long
      sensing
      range
      type
       FX-102 (Note 2)NPN open-collector
      transistor
      FX-102P (Note 2)PNP open-collector
      transistor
      M8 plug-in
      connector type
      FX-102-Z (Note 3)NPN open-collector
      transistor
      FX-102P-Z (Note 3)PNP open-collector
      transistor
      Cable set
      (Note 1)
      FX-102-CC2NPN open-collector
      transistor
      FX-102P-CC2PNP open-collector
      transistor

      Note :

      1)The connector attached cable 2 m 6.562 ft CN-14A-C2 is supplied with the amplifier.

      2)Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd.
      (contact: SPHD-001T-P0.5, housing: PAP-04V-S)

      3)Make sure to use the optional M8 connector attached cable CN-24A-C□.

      Accessory

      CN-14A-C2

      (Connector attached cable 2 m6.562 ft)* Only include cable set type

      FC-FX-1
      (Protection cover)

      Option

      DesignationModel No.Description
      Connector
      attached cable
      CN-14A-C11 m 3.281 ft0.02 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in
      CN-14A-C2 (Note 1)2 m 6.562 ft
      CN-14A-C33 m 9.843 ft
      CN-14A-C55 m 16.404 ft
      Connector
      attached cable
      (Bending-resistant type)
      CN-14A-R-C11 m 3.281 ft
      CN-14A-R-C22 m 6.562 ft
      CN-14A-R-C33 m 9.843 ft
      CN-14A-R-C55 m 16.404 ft
      M8 connector
      attached cable
      CN-24A-C22 m 6.562 ftFor M8 plug-in connector type The connector on one end Cable outer diameter: ø4 mm ø0.157 in
      CN-24A-C55 m 16.404 ft
      ConnectorCN-14ASet of 10 housings and 40 contacts
      Amplifier
      mounting bracket
      MS-DIN-4Mounting bracket for amplifier
      End platesMS-DIN-E
      2 pcs. per set
      When an amplifier moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides.

      Note : The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10□-CC2.

      M8 connector attached cable

      CN-24A-C□

      Amplifier mounting bracket

      MS-DIN-4

      Connector attached cable

      CN-14A(-R)-C□

      Connector

      CN-14A

      Recommended connector

      Contact:
      SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)

      Note:
      Contact the manufacturer for details of the recommended products.

      Recommended crimping tool

      Model No.:
      YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.)

      Note:
      Contact the manufacturer for details of the recommended products.

      Recommended e-CON connector

      Manufactured by 3M Japan Limited
      Adapted connector : 37104-3122-000 FL

      Please refer to "Introducing the 3M™ mini-clamp connector" for details.

      Specifications

      TypeStandard typeLong sensing range type
       Cable set Cable set
      Model
      No.
      NPN outputFX-101(-Z)
      (Note 5)
      FX-101-CC2FX-102(-Z)
      (Note 5)
      FX-102-CC2
      PNP outputFX-101P(-Z)
      (Note 5)
      FX-101P-CC2FX-102P(-Z)
      (Note 5)
      FX-102P-CC2
      Applicable regulations and certificationsCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification
      Supply voltage12 to 24 V DC ±10 % Ripple P-P 10 % or less
      Power consumptionNormal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
      ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
      Output<NPN output type>
      NPN open-collector transistor
      • Maximum sink current: 100 mA
      • Applied voltage: 30 V DC or less (between output and 0 V)
      • Residual voltage: 1.5 V or less (at 100 mA sink current)

      <PNP output type>
      PNP open-collector transistor
      • Maximum source current: 100 mA
      • Applied voltage: 30 V DC or less (between output and +V)
      • Residual voltage: 1.5 V or less (at 100 mA source current)
       Output operationSelectable either Light-ON or Dark-ON, at SET mode
      Short-circuit
      protection
      Incorporated
      External input<NPN output type>
      NPN non-contact input
      • Signal condition
      High: +8 V to +V DC or Open
      Low: 0 to +2 V DC
      (Source current 0.5 mA or less)
      • Input impedance: 10 kΩ approx.

      <PNP output type>
      PNP non-contact input
      • Signal condition
      High: +4 V to +V DC (Sink current 0.5 to 3 mA)
      Low: 0 to +0.6 V DC or Open
      • Input impedance: 10 kΩ approx.
      Response timeEmission frequency 0: 250 μs or less (factory default setting)
      Emission frequency 1: 450 μs or less
      Emission frequency 2: 500 μs or less
      Emission frequency 3: 600 μs or less
      Emission frequency 1: 2.5 ms or less (factory default setting)
      Emission frequency 2: 2.8 ms or less
      Emission frequency 3: 3.2 ms or less
      Emission frequency 4: 5.0 ms or less
      Sensitivity setting2-point teaching / Limit teaching / Full-auto teaching
      Operation indicatorOrange LED (lights up when the output is ON)
      Digital display4 digits (green) + 4 digits (red) LCD display
      Fine sensitivity
      adjustment function
      Incorporated
      Timer functionON-delay / OFF-delay timer, switchable either effective or ineffective
      [Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms]
      Emission amount setting function3-level + Auto setting
      Interference prevention
      function
      Incorporated
      Emission frequency selection method (Note 2)
      (Functions at emission frequency 1, 2 or 3)
      Incorporated
      Emission frequency selection method (Note 2)
      (Functions at emission frequency 1, 2, 3 or 4)
      Ambient
      temperature
      –10 to +55 ℃ +14 to +131
      (If 4 to 7 units are mounted close together: –10 to +50 ℃ +14 to +122 , if 8 to 16 units are mounted close together: –10 to +45 ℃ +14 to +113 ) (No dew condensation or icing allowed),
      Storage: –20 to +70 ℃ –4 to +158
      Ambient
      humidity
      35 to 85 % RH, Storage: 35 to 85 % RH
      Ambient
      illuminance
      Incandescent light: 3,000 ℓx or less at the light-receiving face
      Voltage
      withstandability
      1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3)
      Insulation
      resistance
      20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3)
      Vibration
      resistance
      10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
      Shock
      resistance
      98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
      Emitting element
      (modulated)
      Red LED (Peak emission wavelength: 643 nm 0.025 mil)
      MaterialEnclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT
      Connecting methodConnector (Note 4)
      Cable lengthTotal length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
      WeightNet weight: 15 g approx.
      Gross weight: 35 g approx.
      Net weight: 15 g approx.
      Gross weight: 75 g approx.
      Net weight: 15 g approx.
      Gross weight: 35 g approx.
      Net weight: 15 g approx.
      Gross weight: 75 g approx.
      AccessoryFC-FX-1
      (Protection cover): 1 pc.
      FC-FX-1
      (Protection cover): 1 pc.
      CN-14A-C2
      (Connector attached cable, 2 m 6.562 ft long): 1 pc.
      FC-FX-1
      (Protection cover): 1 pc.
      FC-FX-1
      (Protection cover): 1 pc.
      CN-14A-C2
      (Connector attached cable, 2 m 6.562 ft long): 1 pc.

      Notes:

      1):Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

      2):When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values.
      However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2.

      3):The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.

      4):Connector attached cable CN-14A-C2 is not attached to the models that have no "-CC2" at the end of the model Nos.
      Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd.
      (contact: SPHD-001T-P0.5, housing: PAP-04V-S).

      5):Model Nos. having the suffix "-Z" are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□.

      Dimensions

      • Unit: mm in

      FX-101□
      FX-102□

      Amplifier

      FX-101□ FX-102□

      FX-101(P)-Z
      FX-102(P)-Z

      Amplifier

      FX-101(P)-Z FX-102(P)-Z

      CN-14A-C□
      CN-14A-R-C□

      Connector attached cable (Optional, CN-14A-C2 is attached to FX-101(P)-CC2 / FX-102(P)-CC2)

      CN-14A-C□ CN-14A-R-C□

      • Length L

      Model No.Length L
      CN-14A(-R)-C11,000 39.370
      CN-14A(-R)-C22,000 78.740
      CN-14A(-R)-C33,000 118.110
      CN-14A(-R)-C55,000 196.850

      MS-DIN-4

      Amplifer mounting bracket (Optional)

      MS-DIN-4

      Material:PBT

      MS-DIN-E

      End plate (Optional)

      MS-DIN-E

      Material:Polycarbonate

      I/O Circuit and Wiring diagrams

      NPN output type

      FX-10□(-Z/-CC2)

      I/O circuit diagram

      NPN output type FX-10□(-Z/-CC2) I/O circuit diagram

      Symbols・・・

      D : Reverse supply polarity protection diode
      ZD: Surge absorption zener diode
      Tr : NPN output transistor

      Terminal arrangement diagram


      Connector type

      NPN output type FX-10□(-Z/-CC2) Terminal arrangement diagram Connector type

      Terminal No.Function
      1+V
      2Output
      3External input
      40 V

      M8 plug-in connector type

      NPN output type FX-10□(-Z/-CC2) Terminal arrangement diagram M8 plug-in connector type

      Terminal No.Function
      1+V
      2Output
      3External input
      40 V

      PNP output type

      FX-10□P(-Z/-CC2)

      I/O circuit diagram

      PNP output type FX-10□P(-Z/-CC2) I/O circuit diagram

      Symbols・・・

      D : Reverse supply polarity protection diode
      ZD: Surge absorption zener diode
      Tr : PNP output transistor

      Terminal arrangement diagram


      Connector type

      PNP output type FX-10□P(-Z/-CC2) Terminal arrangement diagram Connector type

      Terminal No.Function
      1+V
      2Output
      3External input
      40 V

      M8 plug-in connector type

      PNP output type FX-10□P(-Z/-CC2) Terminal arrangement diagram M8 plug-in connector type

      Terminal No.Function
      1+V
      2Output
      3External input
      40 V

      Sensing characteristics

      Sensing characteristics can be downloaded at catalog download site.
      Please contact our office if not listed here.

      List of fibers

      Fiber List

      Square Head Fiber

      ■Thru-beam type(one pair set)

      TypeModel
      No.
      Sensing range(mm) (Note1)
      FX-101

      FX-102

      Square
      head
      M3FT-R31100340
      M4FT-R43210640
      FT-R41W250710
      FT-R42W5102,000
      FT-R44Y210640
      M6FT-R60Y6901,890

      ■Reflective type

      TypeModel
      No.
      Sensing range(mm) (Note1)(Note2)
      FX-101

      FX-102

      Square
      head
      M3FD-R31G45150
      FD-R32EG2068
      FD-R33EG722
      FD-R34EG1760
      M4FD-R4160170
      M6FD-R61Y85185

      Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.

      Note2:The sensing range is specified for white non-glossy paper.

      For details of Square Head Fiber, refer to product information page.
      >>Go to "Square Head Fiber"

      Super Quality

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm)
      FX-101

      FX-102

      ThreadedM3FT-30135400
      M4FT-40320870
      Cylindricalø1.5FT-S20135400
      ø3FT-S30320870

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note)
      FX-101

      FX-102

      ThreadedM3FD-3045155
      M4FD-4045155
      M6FD-60140420
      Cylindricalø3FD-S3045155

      Note:The sensing range is specified for white non-glossy paper.

      For details of Super Quality Fiber, refer to product information page.
      >>Go to "Super Quality Fiber"

      Threaded Type

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note 1)
      FX-101FX-102
      ThreadedM3FT-321,3003,600 (Note 2)
      FT-31130340
      FT-31W80240
      M4 FT-43350970
      FT-42300800
      FT-42W260720
      FT-45X340920
      ElbowFT-R40270740
      M14Long rangeFT-14014,00019,600 (Note 2)

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The fiber cable length practically limits the sensing range.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      ThreadedM3 FD-34G2990
      FD-3135140
      FD-31W1560
      FD-32G70190
      FD-32GX75210
      Ultra-small diameterFD-EG302070
      FD-EG31725
      M4FD-4135140
      FD-41W80230
      FD-42G70190
      FD-42GW45140
      M6 FD-62170450
      FD-61120410
      FD-61W80230
      FD-61G120350
      FD-64X75220
      ElbowFD-R60110240

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is specified for white non-glossy paper.

      For details of Threaded Type Fiber, refer to product information page.
      >>Go to "Threaded Type Fiber"

      Cylindrical Type

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note)
      FX-101

      FX-102

      Cylindricalø1FT-S114090
      ø1.5FT-S22230560
      FT-S21130340
      FT-S21W80240
      ø2.5FT-S321,1003,000
      ø3FT-S31W260720
      Ultra-small diameterø3FT-E13619
      FT-E232280
      Side-viewø4FT-V401,0003,100

      Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      Cylindricalø1.5FD-S21
      (Discontinued products)
      2570
      FD-S231750
      ø3FD-S34G2990
      FD-S32120345
      FD-S32W80230
      FD-S3135140
      FD-S33GW45140
      Ultra-small diameterø1.5FD-E13515
      ø3FD-E232070

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is specified for white non-glossy paper.

      For details of Cylindrical Type Fiber, refer to product information page.
      >>Go to "Cylindrical Type Fiber"

      Sleeve

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      ThreadedM3FT-31S130340
      M4FT-42S300800
      CylindricalUltra-small diameterø3FT-E13619
      FT-E232280
      Side-viewø2FT-V23160400
      FT-V2595260
      FT-V24W3590
      ø2.5FT-V30180480

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The fiber cable length practically limits the sensing range.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      ThreadedUltra-small diameterM3FD-EG30S2070
      M4FD-41S35140
      FD-41SW1560
      M6FD-61S130360
      CylindricalUltra-small diameterø1.5FD-E13515
      ø3FD-E232070
      Side-viewø3FD-V302575
      FD-V30W620
      ø5FD-V5040100

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is specified for white non-glossy paper.

      For details of Sleeve Fiber, refer to product information page.
      >>Go to "Sleeve Fiber"

      Flat Type

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note)
      FX-101FX-102
      Flat FT-Z30H1,4003,200
      FT-Z30HW1,4003,200
      FT-Z30E1,2003,200
      FT-Z30EW1,4002,600
      FT-Z307102,300
      FT-Z30W5401,800
      With bossFT-Z20W280730
      FT-Z20HBW100320
      FT-Z40W4101,200
      FT-Z40HBW260720

      Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      FlatWith bossFD-Z20W2 to 321 to 80
      FD-Z20HBW2 to 301 to 90
      FD-Z40W1 to 74200
      FD-Z40HBW1 to 900.5 to 240

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is specified for white non-glossy paper.

      For details of Flat Type Fiber, refer to product information page.
      >>Go to "Flat Type Fiber"

      Narrow Beam

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note 1)
      FX-101FX-102
      Narrow beamFT-KS402,2003,600 (Note 2)
      FT-KV402,2003,600 (Note 2)
      FT-KV40W2,2003,600 (Note 2)
      FT-KV26135560
      FT-KV26H1160500

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The fiber cable length practically limits the sensing range.

      ■Retroreflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      With polarizing filtersFR-Z50HW100 to 550100 to 830
      Wafer mappingFR-KZ22E15 to 20015 to 360
      Narrow beamTop sensingFR-KZ50H20 to 20020 to 350
      Side sensingFR-KZ50E20 to 20020 to 350

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note)
      FX-101FX-102
      Long rangeFD-Z50HW10 to 20010 to 530

      Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      For details of Narrow Beam Fiber, refer to product information page.
      >>Go to "Narrow Beam Fiber"

      Wide Beam

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note 1)
      FX-101FX-102
      Wide beamFT-A323,600 (Note 2)3,600 (Note 2)
      FT-A32W3,600 (Note 2)3,600 (Note 2)
      FT-A111,9003,600 (Note 2)
      FT-A11W1,7003,400
      ArrayFT-AL05250660

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The fiber cable length practically limits the sensing range to 3,600 mm long.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      Wide beamFD-A16120240
      ArrayFD-AL11
      (Discontinued products)
      100285
      FD-AL1280240

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is specified for white non-glossy paper.

      For details of Wide Beam Fiber, refer to product information page.
      >>Go to "Wide Beam Fiber"

      Convergent Reflective Type

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      Glass substrate detectionFD-L32H16 to 300 to 50
      FD-L30A0 to 400 to 50
      FD-L31A5 to 304 to 33
      FD-L22A
      (Discontinued products)
      0 to 190 to 25
      FD-L24A0 to 190 to 21
      FD-L23
      (Discontinued products)
      0 to 280 to 30
      FD-L250 to 250 to 30
      FD-L110 to 80 to 9
      FD-L100 to 4.50 to 5.5
      FD-L213 to 151.5 to 16
      FD-L21W7 to 123 to 14
      General purposeFD-L20H5 to 151 to 30
      Ultla smallFD-L12W1 to 4.50.5 to 7

      Note 1:The sensing range is specified for transparent glass 100 x 100 x t0.7 mm (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm).

      Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      For details of Convergent Reflective Type Fiber, refer to product information page.
      >>Go to "Convergent Reflective Type Fiber"

      Retroreflective Type

      ■Retroreflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      With polarizing filtersFR-Z50HW100 to 550100 to 830
      Wafer mappingFR-KZ22E15 to 20015 to 360
      Narrow beamTop sensingFR-KZ50H20 to 20020 to 350
      Side sensingFR-KZ50E20 to 20020 to 350

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

      For details of Retroreflective Type Fiber, refer to product information page.
      >>Go to "Retroreflective Type Fiber"

      Chemical-resistant

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note)
      FX-101FX-102
      Chemical-resistantFT-Z802Y5203,100
      FT-HL80Y9902,340
      FT-L80Y1,1002,600
      FT-V80Y340800

      Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note1)(Note2)
      FX-101

      FX-102

      Chemical-resistantFD-S60Y140300

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.

      Note 2:The sensing range is specified for white non-glossy paper.

      For details of Chemical-resistant Fiber, refer to product information page.
      >>Go to "Chemical-resistant Fiber"

      Heat-resistant

      ■Thru-beam type (one pair set)

      TypeHeat-resistant temp.Model No.Sensing range (mm) (Note)
      FX-101FX-102
      Heat-resistant350℃FT-H35-M2170490
      FT-H35-M2S6170490
      200℃FT-H20W-M1100300
      FT-H20-M1210540
      130℃FT-H13-FM2250700
      Heat-resistant (joint)200℃FT-H20-J20-S135420
      FT-H20-J30-S135420
      FT-H20-J50-S135420
      FT-H20-VJ50-S150500
      FT-H20-VJ80-S150500

      Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      ■Reflective type

      TypeHeat-resistant temp.Model No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      Heat-resistantThreaded350℃FD-H35-M275280
      FD-H35-M2S675280
      FD-H35-20S85200
      200℃FD-H20-M1120300
      FD-H20-2190280
      130℃FD-H13-FM2100280
      Glass substrate detection convergent reflective300℃FD-H30-L322 to 90 to 17
      250℃FD-H25-L434 to 164 to 23
      FD-H25-L457 to 357 to 38
      180℃FD-H18-L310 to 100 to 25

      Note 1:The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm glass substrate for FD-H30-L32,
      FD-H18-L31, transparent glass 100 x 100 x t0.7 mm for FD-H25-L43 and FD-H25-L45).

      Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      For details of Heat-resistant Fiber, refer to product information page.
      >>Go to "Heat-resistant Fiber"

      One-Touch Connection System Vacuum-resistant Fibers

      ■Thru-beam type

      TypeModel No.Sensing range (mm)(Note 1)
      FX-101FX-102
      Vacuum-
      resistant
      Thru-beamFT-40V110280

      (Note 1):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
      Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      ■Reflective type

      TypeModel No.Sensing range(mm) (Note 1)(Note 2)
      FX-101FX-102
      Vacuum-
      resistant
      Long range
      reflective
      FD-KZ50V25 to 8010 to 220
      Convergent
      reflective
      FD-L10V2.5 to 6.50 to 11

      (Note 1):The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.

      (Note 2):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
      Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
      >>Go to "One-Touch Connection System Vacuum-resistant Fibers"

      Vacuum-resistant

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm)
      FX-101FX-102
      Vacuum-resistantThru-beamFT-H30-M1V-S110280

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note)
      FX-101FX-102
      Vacuum-resistantReflectiveFD-H30-KZ1V-S25 to 8010 to 220
      Convergent reflectiveFD-H30-L32V-S2.5 to 6.50 to 11

      Note:The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm.

      For details of Vacuum-resistant Fiber, refer to product information page.
      >>Go to "Vacuum-resistant Fiber"

      Metal-free

      ■Thru-beam type (one pair set)

      TypeModel No.Sensing range (mm) (Note)
      FX-101FX-102
      ThreadedM4FT-41300800

      Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      ■Reflective type

      TypeModel No.Sensing range (mm) (Note 1, 2)
      FX-101FX-102
      ThreadedM4FD-G4050120
      M6FD-G60100410

      Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

      Note 2:The sensing range is specified for white non-glossy paper.

      For details of Metal-free Fiber, refer to product information page.
      >>Go to "Metal-free Fiber"

      Cautions For Use

      • Never use this product as a sensing device for personnel protection.
      • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

      Using in combination with the FX-300 / FX-410 series

      • The FX-100 series does not use the horizontal connectors that are used with the FX-300 / FX-410 series. Please note that horizontal connection cannot be performed using a connector attached cable. In addition, the optical communication function is not equipped on the FX-100 series, so it is unable to perform interference prevention for use with the FX-300 / FX-410 series.
        If using the FX-100 series together with the FX-300 / FX-410 series side-by-side, please set the same models together in groups.

      Mounting

      <When using a DIN rail>

      How to mount the amplifier

      [1]Fit the rear part of the mounting section of the amplifier on a 35 mm 1.378 in width DIN rail.

      [2]Press down the rear part of the mounting section of the unit on the 35 mm 1.378 in width DIN rail and fit the front part of the mounting section to the DIN rail.

      Mounting When using a DIN rail How to mount the amplifier

      How to remove the amplifier

      [1]Push the amplifier forward.

      [2]Lift up the front part of the amplifier to remove it.

      Mounting When using a DIN rail How to remove the amplifier

      Note:Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break.

      <When using screws with washers>

      • Use M3 screws with washers for mounting. The tightening torque should be 0.5 N·m or less.

      Mounting When using screws with washers

      Wiring

      • Make sure that the power supply is OFF while adding or removing the amplifiers.
      • Note that if a voltage exceeding the reted range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged.
      • Note that short-circuit of the load or wrong wiring may burn or damage the product.
      • Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction.
      • Verify that the supply voltage variation is within the rating.
      • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
      • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
      • Make sure to use the quick-connection cable (optional) for the connection of the controller.
        Extension up to total 100 m 328.084 ft is possible with 0.3 mm2 or more, cable. However, in order to reduce noise, make the wiring as short as possible.

      Part description

      Part description

      Setting mode

      • Setting mode appears after the MODE key is pressed for 2 sec. in RUN mode.
      Setting itemFactory settingDescription
      Teaching mode

      Threshold value can be set in 2-point teaching, limit teaching, or full-auto teaching.
      Output operation setting


      [Dark-ON]
      Light-ON or Dark-ON can be set.
      Timer operation setting


      [Without timer]
      Without timer, ON delay timer, or OFF delay timer can be set.
      Timer delays setting


      [ON-delay timer: 10 ms]


      [OFF-delay timer: 10 ms]
      When setting ON delay timer or OFF delay timer in the timer operation setting mode, timer delays can be set.
      ・When timer is not set, this mode is not displayed.
      Emission amount setting


      *[Level 3]
      In case incident light intensity is saturated, emission amount can be reduced.
      Emission frequency settingFX-101


      [0 (Response time:250 μs or less)]
      FX-102


      [1 (Response time:2.5 ms or less)]
      When using the fiber heads in parallel, interference can be prevented by setting different emission frequency. However, when emission frequency 0 is set, interference cannot be prevented. Response time corresponds to emission frequency.

      PRO mode

      • PRO mode appears after the MODE key is pressed for 4 sec. in RUN mode.
      Setting itemFactory settingDescription
      Shift setting
      [Shift amount 15 %]
      Shift amount can be selected from 0 to 80 % in the limit teaching. Select 0 % when it is desired to set the present incident light intensity as a threshold value.
      External input setting
      [Emission halt]
      External input can be selected from emission halt, limit teaching [+], limit teaching [-], full-auto teaching, ECO (Note 1), 2-point teaching or emission amount test. When setting the incident light intensity test “”, output turns ON / OFF every 100ms when the rate of incident light intensity and threshold value is less than half of the set shift amount (for example, when the rate of incident light intensity and threshold value is within ±10 % for 20 % of shift amount) at external input.
      Threshold value-storing setting mode (Note 2)Threshold value set at the limit teaching, full-auto teaching or 2-point teaching by external input is stored. When selecting Auto in the emission amount setting mode, the set emission amount level is also stored.
      Threshold value follow-up cycle setting (Note 3)When incident light intensity exceeds threshold value, this mode can change the threshold value with each set cycle depending on variations of the incident light intensity. The follow-up shift amount is same as the one set in the shift setting mode. However, the threshold value is not stored.
      GETA function setting (Note 4, 5)Variations can be reduced by correcting the present incident light intensity in each amplifier to a target value. Target value to offset incident light intensity can be selected from 0 to 2,000 by 100 unit each. For example, if the target value is set to 2,000 when the incident light intensity is 1,500, the incident light intensity becomes 2,000.
      ECO settingIt is possible to light up / turn off the digital display. When ECO setting mode is ON, the display turns off in 20 sec. approx. in RUN mode. To light up the display again, press any key for 2 sec. or more.
      Digital display inversion settingDigital display can be inverted.
      Threshold value margin settingMargin for threshold value to the present incident light intensity can be checked. When there is no margin, it is possible to make the digital display blink.
      : Set to “OFF”: does not function
      : Green blinks.
      : Red blinks.
      : Red and green blink.
      : When conducting limit teaching or 2-point teaching by external input, in case the rate of reference incident light intensity and threshold value after teaching is 200% or more, or in case it is less than half of the shift amount, output turns ON / OFF every 100 ms. (Note 6)
      Setting copyThe settings of the master side amplifier can be copied to the slave side amplifier.
      For details, refer to “Setting copy function”.
      ResetReturns to default settings (factory settings.)

      PRO mode Notes

      Setting copy function

      Refer to the "Instruction Manual" for details.

      Others

      • This product has been developed / produced for industrial use only.
      • Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
      • Take care that the product is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing performance.
      • This product is suitable for indoor use only.
      • Avoid dust, dirt, and steam.
      • Take care that the product does not come in contact with oil, grease, organic solvents, such as thinner, etc., strong acid or alkaline.
      • This product cannot be used in an environment containing inflammable or explosive gases.
      • Never disassemble or modify this product.
      • EEPROM is adopted to this product. It is not possible to conduct teaching 100 thousand times or more, because of the EEPROM’s lifetime.

      Quick setting function

      Quick setting function

      Note:The emission amount of Level 2 (ON) is about 40% of that of Level 3 (OFF).

      Code setting function

      Code setting function

      MENU

      Recently checked products

      Recently checked product numbers